====== HP Raid Utils ====== | ====== HP Raid Utils ====== | ||
+ | |||
+ | HP has replaced command tool hpacucli with hpssacli for later versions of HP Raid Controllers. This is really stupid done by HP. The genius changing a command name should be punished by whip. | ||
+ | |||
+ | In order to get my existing scripts to work, I have created a soft link from hpacucli -> hpssacli in /usr/sbin. | ||
# hpacucli ctrl all show config | # hpacucli ctrl all show config | ||
Line 14: | Line 18: | ||
| | ||
/tmp/test is output file for result | /tmp/test is output file for result | ||
+ | |||
+ | ===== Spare drives ===== | ||
+ | |||
+ | ==== Remove spare drives ==== | ||
+ | |||
+ | Remove spare drive from Array I | ||
+ | |||
+ | # hpacucli ctrl slot=1 array I remove spares=4E:1:17 | ||
+ | | ||
+ | ==== Adding spare drives ==== | ||
+ | |||
+ | Add two global hot spares | ||
+ | |||
+ | # hpacucli ctrl slot=1 array all add spares=2E:1:18,4E:1:17 | ||
===== Smartctl hints for HP smart array (CCISS driver) ===== | ===== Smartctl hints for HP smart array (CCISS driver) ===== | ||